What will be run in
Texas will depend on the outcome of the Texas certification decision, won't
it?
Nel
----- Original Message -----
Sent: Wednesday, September 25, 2002 9:48
AM
Subject: Re: Error Encountered with
Display Bug #1209
So, I am back to we should be using BS 4.1.13 in
Texas installations? Les
This is now fixed and will be in BS 4.1.13 and
4.3.10.Additional Comments >From
Ravina
Dhami 2002-08-13 15:23
tested and passed in 4.1.13. Need to verify
in 4.3.10
tested and passed in 4.3.10
______________________________________________________________________________________________________________
----- Original Message -----
Sent: Wednesday, September 25, 2002 11:24
AM
Subject: Re: Error Encountered with
Display
> As a clarification from the Development side, Lesley's problem
with the > missing Start button is logged as bug number 1209 and has
already been > resolved. > > Nel > ----- Original
Message ----- > From: "Lesley Thompson (earthlink)" <lesleytdiebold@earthlink.net> > To: <support@dieboldes.com> >
Sent: Wednesday, September 25, 2002 6:20 AM > Subject: Re: Error
Encountered with Display > > > > Franklin County,
TX > > yesterday (9-24-02) > > WinCE 3.0 Aug8th > >
BS 4.1.11 > > GEMS 1.17.23 > > > > Experienced
'blank' green box where "START" should display > > > >
Les > > >
____________________________________________________________________________ >
> __________________________________ > > > > Lesley Koop
Thompson > > Customer Service Project Manager > > Diebold
Election Systems, Inc. > > 415-235-6553 (office cell) > >
512-413-7618 (cell) > > lesley@dieboldes.com >
> > > ----- Original Message ----- > > From: "Robert G.
Diekmann" <robertd@dieboldes.com> >
> To: <support@dieboldes.com> >
> Sent: Tuesday, September 24, 2002 3:44 PM > > Subject: Re: Error
Encountered with Display > > > > > > >
Ian: > > > > > > This error occurred repeatedly and
was reported during the IACREOT > > > convention. I am not
sure of the versions being used at that time. > > > > >
> Bob Diekmann > > > ----- Original Message ----- > >
> From: "Ian S. Piper" <ian@dieboldes.com> > > > To: "Support (E-mail)" <support@gesn.com> > >
> Cc: "'Greg Gramig'" <greggramig@dieboldes.com>; "Daryl
Graves (E-mail)" > > > <darylg@dieboldes.com> >
> > Sent: Tuesday, September 24, 2002 9:43 AM > > > Subject:
FW: Error Encountered with Display > > > > > > >
> > > > > > > > > > > Has anybody seen
the error as described below? > > > > > > > >
The R6 unit is loaded with fbootloader 1.0.2, Windows CE 3.0 Aug 8th >
> > > edition, and BallotStation 4.1.11. > > >
> > > > > Ian > > > > > > >
> -----Original Message----- > > > > From: Greg Gramig
[mailto:greggramig@dieboldes.com] > > > > Sent: Tuesday,
September 24, 2002 9:32 AM > > > > To: Ian S. Piper >
> > > Cc: Daryl Graves > > > > Subject: Error
Encountered with Display > > > > > > > >
Ian, > > > > > > > > KSU pointed out an anomaly
as indicated in this screen shot from a > > digital > > >
> camera of the actual unit, s/n: 139880. > > > > >
> > > The green box on bottom right of screen is not displaying the
correct > > data > > > > (it is blank and possibly
incorrect size. > > > > > > > > The unit and
memory card has been quarantined and marked should that > >
need > > > to > > > > be evaluated. > >
> > > > > > Please let me know how you would like to
proceed. > > > > > > > > Thank you, > >
> > > > > > Greg Gramig > > > > >
> > > > > > > > > > > > > >
>
|