Tulare called this AM. Vern says the reader gives constant "No
back left timing mark" and other timing mark messages when using the
feeder. The read heads were all swapped out this fall. Question
on this error message. Does this imply that the reader is running too fast
or too slow? That is, does the clock run expecting a certain speed of
ballot feed and during the time cycle doesn't see 41 marks (11"), ie its not
seeing 41 marks, and is too slow? Or is it the reverse, it is running too
fast? I guess if its too fast, it could not be having enough time to set
itsef and read first mark. I have resolved this issue in past by
"shimming" readers in the field, but I would like to better understand what this
message means. If we need to fly someone from McKinney into Fresno and
have them drive to Visalia, we need to do this relatively quickly as ballot
processing starts in two weeks. I am seeing the same types of messages in
Placer, but not to the same degree.
Steve Knecht
Diebold Election Systems 415-893-9941 office 415-893-9951 fax 415-225-6591 cell |