[Date Prev][Date Next] [Chronological] [Thread] [Top]

RE: Central Count Lucid Readers



The same torque setting does not apply to the ones holding the housing halves together.
 
Ian
-----Original Message-----
From: owner-support@gesn.com [mailto:owner-support@gesn.com]On Behalf Of Don Biszmaier
Sent: November 07, 2000 7:41 PM
To: support@gesn.com
Subject: Re: Central Count Lucid Readers

Steve: According to the screw gurus and a $260 torque screwdriver it should be 4 in/lbs (I think that's the term) on the screws holding the read heads in. I'm not sure if the same applies to the ones holding the read heads together.
More sacrifices: Don
-----Original Message-----
From: Steve Knecht <skglobal@earthlink.net>
To: support@gesn.com <support@gesn.com>
Date: Tuesday, November 07, 2000 12:24 PM
Subject: Fw: Central Count Lucid Readers

After taking apart four (4) Lucid readers this AM to adjust them (these are from the 10 sent from McKinney last week to Santa Barbara) I can tell you that the four "internal" screws with nuts on them ARE NOT close to being consistently torqued down.  Some are very loose, while others on the same board are tightly screwed down.  Most seem very tight.
----- Original Message -----
Sent: Monday, November 06, 2000 8:40 PM
Subject: Central Count Lucid Readers

Marin and Humboldt both called yesterday stating they can not process their ballots thru their central count units.  Over half their ballots get "no ender", "no left timeing mark", "calibration error" etc.
 
Mike and I have been "loosening" the inner screw adjustments in Santa Barbara to get them working and now they work fine.  Clearly with folds, the ballot path must be set differently for central count than for the normal precinct count, whether we like it or not.  This is not an easy operation to do in the field, and not one doable by most customers. 
 
We need to determine an appropriate path clearance that includes folds for central count units during the manufacturing process and clearly mark those units as central count vs. the precinct count units. I will be referring customer complaints and letters regarding this to Larry D. and Ian.